12KW 15kva Online Ups 0.8 Power Factor Industrial Ups Power Supply
Product Details:
Place of Origin: | Guangdong, China |
Brand Name: | ZGD |
Certification: | CE |
Model Number: | ZGD3315 |
Payment & Shipping Terms:
Minimum Order Quantity: | 10 sets |
---|---|
Price: | $600.00/Sets 1-9 Sets |
Packaging Details: | Carton packaging |
Delivery Time: | 7~15 working days |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 10000 Piece/Pieces per Month |
Detail Information |
|||
Phase: | Three Phase | Weight: | 120kg |
---|---|---|---|
Type: | On-line | Product Name: | Online UPS Systems |
Capacity: | 15KVA | Wave Form: | Pure Sine Wave |
Certificate: | CE,ULRohs,GS,TUV | Input Voltage: | 110-300VAC |
Transfer Time: | 0ms | Port: | Shenzhen |
Highlight: | 12KW 15kva Online Ups,12KW Industrial Ups Power Supply,15kva Industrial Ups Power Supply |
Product Description
Pure Sine Wave Low Frequency Online UPS 15KVA Power Supply With 0.8 Power Factor For Industrial Use
High intelligence and reliable power supply:
ZGD330 provides maximum protection for vital mission-critical networks, security applications (electro- medical)and industrial applications thanks to its outstanding mechanical and electrical design.
The load is powered continuously by the inverter with a filtered, stabilized and regulated sine wave supply. The input and output EMI filters considerably increase the immunity of the load to mains disturbances and surges.
The ZGD330 uses on-line double conversion technology (VFI) with isolation transformer on the inverter output.
The ZGD330 is supplied with Watch & Save 3000 software as standard and can be remotely monitored
using the Power Net Guard system from anywhere in the world. Additional battery extension packs allow the standard battery routine to be extended up to several hours.
Minimum impact on supplies easy sources:
Input current distortion <4% for the ZGD330 with filter with sinusoidal absorption to remove the risk of resonance with other input supply users or phase shift capacitor sets. The absorbed current distortion is independent of input supply parameters such as impedance. This enable ZGD330 to deliver maximum performance levels regardless of the installation environment. With these input features ZGD330 can achieve significant savings in terms of sizing and power supply sources isolation transformers and generators over less sophisticated power systems.
Maximum battery care:
Battery deep discharge protection;
Temperature compensating charger;
Built-in automatic and manual battery test feature.
Model | ZGD33 15K | |||||||||||
CAPACITY | 12 KW | |||||||||||
INPUT | ||||||||||||
Nominal Voltage | 3 x 380VAC/400VAC (3Ph + N) | |||||||||||
Acceptable Voltage Range | 305VAC ~ 460VAC | |||||||||||
Frequency | 50/60 Hz ± 10 % | |||||||||||
INVERTER | ||||||||||||
Nominal Voltage | 3 x 380VAC/400VAC (3Ph + N) | |||||||||||
Precision | Stationary: ±1% ; Transitory: ±5% (load variations 100-0-100%) | |||||||||||
Frequency | 50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz | |||||||||||
Max. Synchronisation Speed | ±1 Hz/s | |||||||||||
Waveform | Pure Sinewave | |||||||||||
Total Harmonic Distortion (THDv) | < 2% (Linear Load) ; < 5% (Non-linear Load) | |||||||||||
Phase Displacement | 120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load) | |||||||||||
Dynamic Recovery Time | 3 cycles at 98 % of the static value | |||||||||||
Admissible Overload | 110% for 10min; 150% for 60sec ; >160% for 200ms | |||||||||||
Admissible Crest Factor | 3:1 | |||||||||||
Admissible Power Factor | 0.6~1 (inductive or capacitive) | |||||||||||
Current Limit | High overload, short-circuit: RMS Voltage Limit ; High Crest-Factor current: Peak Voltage Limit | |||||||||||
STATIC BYPASS | ||||||||||||
Type | Solid state | |||||||||||
Voltage | 3 x 380VAC/400VAC (3Ph + N) | |||||||||||
Frequency | 50/60 Hz | |||||||||||
Activation Criterion | Microprocessor control | |||||||||||
Transfer Time | Zero | |||||||||||
Admissible Overload | 150% for 1 hour; 180% for 30sec; >200% for 200ms | |||||||||||
Transfer to Bypass | Immediate, for overloads above 160% | |||||||||||
Retransfer | Automatic after alarm clear | |||||||||||
BATTERY & CHARGER | ||||||||||||
Battery Type and Numbers | 12VDC x 32 pcs (29~32 pcs adjustable) | |||||||||||
Nominal Battery Voltage | 384 VDC (Based on 32pcs batteries) | |||||||||||
Charging Method | CC/CV | |||||||||||
Charging Current | Default 10A, Max. = Capacity / Battery Voltage | |||||||||||
Charging Voltage | 432 VDC (Based on 32pcs batteries) | |||||||||||
PHYSICAL | ||||||||||||
Dimension D x W x H (mm) |
656 x 405 x 817 | |||||||||||
Net Weight (kgs) | 118 |







We are based in Guangdong, China, start from 2013,sell to Domestic Market(50.00%),Southeast Asia(5.00%). There are total about 101-200 people in our office.
2. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
3.what can you buy from us?
Industrial UPS,Capacitive UPS,Modular UPS,High Frequency UPS,Low Frequency UPS
4. why should you buy from us not from other suppliers?
As a manufacturer with over 10 years of experience, Shenzhen ZGD Technology Co., Ltd. has more than 10 production lines which can produce 100,000 pieces of UPS every month. Over 10% of our staff members are engineers and professional technicians and more
5. what services can we provide?
Accepted Delivery Terms: FOB,CIF,EXW;
Accepted Payment Currency:USD,CNY;
Accepted Payment Type: T/T,L/C,Western Union;
Language Spoken:English,Chinese